MTA-MA-017: Difference between revisions
No edit summary |
Jacob Sommer (talk | contribs) m (1 revision imported) |
(No difference)
| |
Revision as of 01:37, 5 March 2026
| Administrative Items | |
|---|---|
| Date | 12/15/2020 |
| Functional Area Where Benefits Will Be Realized | Maintenance
Quality Control |
| Reference Implementation Guidance | 2018 TIP Award - Submittal 14 (ID: 11240582)
EPRI Nondestructive Evaluation: Buried Pipe NDE Reference Guide, R3 (EPRI 3002004395) EPRI Nondestructive Evaluation: Assessment and Development of Buried Pipe NDE Technology, R1 (EPRI 3002010027) |
| Industry SME | EPRI – Steve Kenefick
Contact: NuclearPlantMod@epri.com |
| Previous Implementation | Please contact EPRI for implementation examples and contacts. |
| Implementation Enablers | N/A |
| SWEEP Score |
|
| Applicability | All reactor types
All geographic regions |
| Keywords | Robotic Examination; Buried Piping Systems; Piping Nondestructive Examination |
| Business Case Analysis Cross-Reference | N/A |
Description
Robotic crawlers can be used to perform internal inspections of buried or other difficult to access piping systems. Crawlers can support visual inspections with a camera and/or volumetric examinations with non‑destructive examination (NDE) equipment. These inspections require only a single access point to the pipe and can be performed on a range of piping sizes. Performing in‑line inspections eliminates the need for excavation to access the pipe. The crawler can use the various NDE techniques, including Electro Magnetic Acoustic Transducer (EMAT) ultrasonic testing (UT) technology. Utilizing EMAT allows for 100 % volumetric inspection of protected and/or sleeved ferromagnetic piping segments without removing protective coatings. Selection guidance of the appropriate NDE is provided in EPRI’s buried pipe reference guide.
Benefits
Benefits Estimate
Level 2 – Savings are greater than $1 million per utilization but less than $5 million.
Benefits Description
- Reduction of cost to inspect piping systems that are difficult to access, particularly buried piping where excavation is required.
- For some NDE techniques, reduction of cost by eliminating the need to remove and reapply protective coatings to perform inspections.
- Reduction of risk of damaging buried infrastructure and impact to station equipment.
- Increased resolution of inspection through 100 % volumetric examination, reducing risk of missing localized degradation or other anomalies.
- Increased schedule flexibility due to short inspection times in comparison to fully excavated and prepped piping system.
- Increased safety because maintenance personnel are not required to enter confined spaces and eliminating inherent risks of creating pipe entry points (e.g., cutting pipe).
Costs and Schedule
Cost
Level 3 – Implementation cost is less than $1 million.
Schedule
Between six months and a year to develop technical justification to use crawler in lieu of manual inspection. Approximately one day inspection per line.
Scope Context
Per Piping System. Costs and Benefits will vary based on size and scope of piping system to be inspected.
Risks
Schedule risk associated with first use of an in‑situ NDE technique at a specific site. Performing a technical justification prior to committing to a new NDE technique will mitigate this risk.