MTA-MA-011: Difference between revisions
No edit summary |
Jacob Sommer (talk | contribs) m (1 revision imported) |
(No difference)
| |
Revision as of 01:37, 5 March 2026
| Administrative Items | |
|---|---|
| Date | 12/15/2020 |
| Functional Area Where Benefits Will Be Realized | Maintenance
Engineering |
| Reference Implementation Guidance |
Continuous On-Line Monitoring: Couplings, Gear Type – Grease Lubricated (EPRI 3002012775) Continuous On-Line Monitoring: Couplings, Disc or Diaphragm Type (EPRI 3002012776) Continuous On-Line Monitoring: Couplings, Elastomeric Type – Jaw or Spider Insert (EPRI 3002012777) EPRI Preventive Maintenance Basis Database (PMBD) (EPRI 3002005428) |
| Industry SME |
EPRI – Mike Taylor Contact: NuclearPlantMod@epri.com |
| Previous Implementation | Please contact EPRI for implementation examples and contacts. |
| Implementation Enablers |
|
| SWEEP Score |
|
| Applicability | All reactor types
All geographic regions |
| Keywords | On-line monitoring; couplings; equipment reliability; condition-based maintenance; quick guides; vibration |
| Business Case Analysis Cross-Reference | N/A |
Description
Data acquisition and processing tools have reached the point where Continuous Online Monitoring (COLM) of equipment is possible and cost‑effective. COLM can be used to transition from time‑based preventative maintenance (PM) to condition‑based maintenance (CBM), which reduces maintenance costs by eliminating or reducing premature maintenance activities. COLM also provides valuable insights into equipment health that may help to detect incipient failures before major equipment damage. This MTA specifically applies to the vibration monitoring of couplings.
A coupling connects two shafts together at their ends to transfer motion. To function properly, couplings require routine inspection and maintenance (e.g., vibration analyses). Historically, these inspections and maintenance have been performed through time‑based periodic maintenance. Technology advances in sensors, wireless communications, and data analysis now enable continuous monitoring and trending of various component parameters. Couplings have been historically linked to equipment failures from shaft misalignment or improper lubrication; monitoring couplings would provide benefits in avoided costs. Additionally, properly implementing coupling COLM could allow for the elimination of existing inspection activities or a transition to CBM.
Benefits
Benefits Estimate
Level 1 – Savings are less than $1 million per year. Potential savings are achieved through eliminated maintenance tasks or extended maintenance intervals.
Benefits Description
- Potential labor savings for eliminated or extended PM and inspection tasks by transitioning to CBM. As an example, vibration analyses of couplings could be replaced with COLM.
- Early detection of equipment degradation, resulting in reduced equipment forced outages and corrective maintenance (CM) costs.
- Improved visibility to asset or system condition through more frequent data collection.
- Reduced risk of equipment unreliability caused by maintenance, because COLM replaces PM items or extends the maintenance interval.
Costs and Schedule
Cost
Level 3 – Implementation costs should be less than $1 million. These costs include the sensors, installation, and software. This cost can be shared site or fleet‑wide if other components implement OLM.
Schedule
Six months to two years, which includes planning and implementing new sensors.
Scope Context
Per unit. All rotating equipment have some sort of coupling that can be monitored. Results for multi‑unit sites or across a fleet should be scaled, accounting for any potential efficiencies in larger deployments.
Risks
IT risks associated with integrating with existing plant network, data storage, and analysis software. Addressing IT concerns at the requirements phase of the project (for example, how the sensor data will be gathered and used) will mitigate this risk.
Sensors can vary in implementation difficulty and cost.