MTA-WM-002: Difference between revisions
(Created page with "{{DISPLAYTITLE:Reduce Dose and Labor Hours using Digital Fuel Move Sheets (DFMS) - MTA-WM-002}} {{MTATemplate|| | Date |12/14/2021 | Functional Area Where Benefits Will Be Realized | Work Management Nuclear Fuels Records Management | Reference Implementation Guidance | 2020 NEI TIP Awards – Submittal 59 (ID: 13325413) | Industry SME | EPRI – Erik Mader Contact: NuclearPlantMod@epri.com | Previous Implementation | This improvement has been implemented at sever...") |
Jacob Sommer (talk | contribs) m (1 revision imported) |
(No difference)
| |
Revision as of 01:37, 5 March 2026
| Administrative Items | |
|---|---|
| Date | 12/14/2021 |
| Functional Area Where Benefits Will Be Realized | Work Management
Nuclear Fuels Records Management |
| Reference Implementation Guidance | 2020 NEI TIP Awards – Submittal 59 (ID: 13325413) |
| Industry SME | EPRI – Erik Mader
Contact: NuclearPlantMod@epri.com |
| Previous Implementation | This improvement has been implemented at several nuclear plants. Please contact the EPRI SME for additional information. |
| Implementation Enablers | Wi‑Fi or connection to a wired network for data transfer on the refuel floor. Wi‑Fi enabler guidance includes:
|
| SWEEP Score |
|
| Applicability | All reactor types
All geographic regions |
| Keywords | DFMS, digital fuel move sheet, fuel and core components, work management, fuel move, move sheets, human performance tools, HU tools |
| Business Case Analysis Cross-Reference | N/A |
Description
Fuel and Core Component Move Sheets are official records used by fuel handlers, supervisors, and operators to conduct and document the movement of nuclear fuel and non‑fuel core components. For Special Nuclear Material reporting purposes, fuel move information has been historically transcribed from paper move sheets to the site’s tracking database. Traditional pen‑to‑paper move sheets can become contaminated on the refuel floor, are inefficient to revise, and present opportunities for human error such as move sheets containing inaccurate or missing information and legibility issues. The transition from paper‑based to DFMS streamlines the movement guidance process; a process which can be performed thousands of times annually for a generating unit. DFMS electronically document procedural step completion on an electronic tablet device. DFMS increase productivity and efficiency of the fuel moves thereby decreasing move time, potentially on critical path, and overall dose to staff as well as improve the accuracy and timeliness of reporting by reducing the administrative transcription burden.
Benefits
Benefits Estimate
Level 1 – Savings are less than $1 million per year per unit. For units with the refuel floor on critical path, estimated savings are ≥ $50,000 per refueling outage. Savings are largely driven by increased generation, dose reduction and decreased staff labor.
Benefits Description
- Reduction in refuel outage duration by improving efficiency of the critical path move sheet revision process.
- Reduction in dose to staff by saving time spent on the fuel move process.
- Reduction in human performance delays associated with lost, illegible, incomplete, or inaccurate move sheets.
- Improvement in timeliness and quality of reporting by reducing administrative transcription burden and incorporating electronic documentation.
- Reductions in refuel floor distractions and dose to the outage coordinator by having a live‑time fuel move sheet available in the control room and therefore minimizing in‑person checks on fuel movement status.
- Improvement in metrics with live‑time monitoring and observation of progress.
- Reduction in waste disposal costs associated with contaminated dry active waste.
- Reduction in material costs associated with printing and compiling move sheets.
Costs and Schedule
Cost
Level 3 – Implementation cost is less than $1 million. Estimated implementation costs are on the magnitude of $100,000 per unit and less on a fleet‑wide basis. Ongoing costs are expected to be much lower annually.
Schedule
Six months to one year.
Scope Context
Per unit. Initial implementation costs include the non‑safety‑related software (design, process, integration, and initial training), procedure updates, and tablet device procurement for field use. Approximately 5‑10 devices are used for a single unit. Ongoing costs are driven by software maintenance and technical support and can vary by year based on desired enhancements. DFMS software and ongoing software updates can be used across a multi‑unit site or fleet. Therefore, implementing DFMS across multiple units is expected to decrease the per‑unit implementation cost and associated payback period.
Risks
- IT risks such as cybersecurity and Electromagnetic Compatibility (EMC) are associated with integrating the DFMS devices with the existing plant network.
- Cybersecurity: The system must be properly segmented and implemented to avoid an increase in vulnerability to cybersecurity threats. Following appropriate utility practices to satisfy the NRC cybersecurity requirements will mitigate this risk.
- EMC: EMC must be considered to ensure that wireless signals do not adversely affect nearby equipment. Following the EPRI and U.S. NRC EMC guidance for equipment EMC qualification and maintaining a minimum separation distance, if required, will mitigate this risk.
- If the device loses network connection during the move process, the DFMS will be unavailable for use and could cause schedule delays. Maintaining a plant network connection and operable equipment in the high humidity environment present on the refueling bridge may present a challenge. Printing a backup move sheet to use if network connection becomes unavailable will mitigate this risk.